Modifying Structuring Configurations (Recommended)
Function
This API is used to modify structuring configurations using a structuring template.
URI
PUT /v3/{project_id}/lts/struct/template
Parameter |
Mandatory |
Type |
Description |
---|---|---|---|
project_id |
Yes |
String |
Project ID. For details about how to obtain a project ID, see Obtaining the Project ID, Account ID, Log Group ID, and Log Stream ID. Minimum: 32 Maximum: 32 |
Request Parameters
Parameter |
Mandatory |
Type |
Description |
---|---|---|---|
X-Auth-Token |
Yes |
String |
User token obtained from IAM. For details about how to obtain a user token, see Obtaining a User Token. Minimum: 1000 Maximum: 2000 |
Content-Type |
Yes |
String |
Set this parameter to application/json;charset=UTF-8. Minimum: 30 Maximum: 30 |
Parameter |
Mandatory |
Type |
Description |
---|---|---|---|
log_group_id |
Yes |
String |
Log group ID. For details about how to obtain a log group ID, see Obtaining the Project ID, Account ID, Log Group ID, and Log Stream ID. Minimum: 36 Maximum: 36 |
log_stream_id |
Yes |
String |
Log stream ID. For details about how to obtain a log stream ID, see Obtaining the Project ID, Account ID, Log Group ID, and Log Stream ID. Minimum: 36 Maximum: 36 |
template_id |
Yes |
String |
Template ID. When the system template is used, the current attribute can be empty. Minimum: 0 Maximum: 36 |
template_name |
Yes |
String |
Template name, which cannot be empty and will be verified. Minimum: 1 Maximum: 64 |
template_type |
Yes |
String |
Type of the template. The value can be built_in (system templates) or custom (custom templates). For details about system template types, see section "Log Search and Analysis" > "Cloud Structuring Parsing" > "Structuring Templates" in the LTS User Guide. |
demo_fields |
No |
Array of FieldModel objects |
Example field array. You only need to enter the fields whose status is different from that of is_analysis in the template. |
tag_fields |
No |
Array of FieldModel objects |
Tag field array. You only need to enter the fields whose status is different from that of is_analysis in the template. |
quick_analysis |
No |
Boolean |
Indicates whether to enable quick analysis for demo_fields and tag_fields. If this parameter is set to true, quick analysis is enabled for all fields. If this parameter is left blank or set to false, is_analysis in the template is used to determine whether to enable quick analysis. |
Response Parameters
Status code: 201
Parameter |
Type |
Description |
---|---|---|
- |
String |
Status code: 400
Parameter |
Type |
Description |
---|---|---|
error_code |
String |
Error code. |
error_msg |
String |
Error message. |
Status code: 500
Parameter |
Type |
Description |
---|---|---|
error_code |
String |
Error code. |
error_msg |
String |
Error message. |
Example Requests
-
Modifying an ELB system template
PUT https://{endpoint}/v3/{project_id}/lts/struct/template { "log_group_id" : "17f23e52-a23d-46e0-8bc5-xxxxxxxxxxxx", "log_stream_id" : "b4d56d47-b4c4-453e-9047-xxxxxxxxxxxx", "demo_fields" : [ { "field_name" : "msec", "is_analysis" : false }, { "field_name" : "access_log_topic_id", "is_analysis" : false }, { "field_name" : "time_iso8601", "is_analysis" : false }, { "field_name" : "log_ver", "is_analysis" : true }, { "field_name" : "remote_addr", "is_analysis" : true }, { "field_name" : "remote_port", "is_analysis" : false }, { "field_name" : "status", "is_analysis" : false }, { "field_name" : "request_method", "is_analysis" : false }, { "field_name" : "scheme", "is_analysis" : true }, { "field_name" : "host", "is_analysis" : true }, { "field_name" : "router_request_uri", "is_analysis" : true }, { "field_name" : "server_protocol", "is_analysis" : true }, { "field_name" : "request_length", "is_analysis" : true }, { "field_name" : "bytes_sent", "is_analysis" : false }, { "field_name" : "body_bytes_sent", "is_analysis" : false }, { "field_name" : "request_time", "is_analysis" : false }, { "field_name" : "upstream_status", "is_analysis" : false }, { "field_name" : "upstream_connect_time", "is_analysis" : false }, { "field_name" : "upstream_header_time", "is_analysis" : false }, { "field_name" : "upstream_response_time", "is_analysis" : false }, { "field_name" : "upstream_addr", "is_analysis" : false }, { "field_name" : "http_user_agent", "is_analysis" : false }, { "field_name" : "http_referer", "is_analysis" : false }, { "field_name" : "http_x_forwarded_for", "is_analysis" : false }, { "field_name" : "lb_name", "is_analysis" : false }, { "field_name" : "listener_name", "is_analysis" : false }, { "field_name" : "listener_id", "is_analysis" : false }, { "field_name" : "pool_name", "is_analysis" : false }, { "field_name" : "member_name", "is_analysis" : false }, { "field_name" : "tenant_id", "is_analysis" : false }, { "field_name" : "eip_address", "is_analysis" : false }, { "field_name" : "eip_port", "is_analysis" : false }, { "field_name" : "upstream_addr_priv", "is_analysis" : false }, { "field_name" : "certificate_id", "is_analysis" : false }, { "field_name" : "ssl_protocol", "is_analysis" : false }, { "field_name" : "ssl_cipher", "is_analysis" : false }, { "field_name" : "sni_domain_name", "is_analysis" : false }, { "field_name" : "tcpinfo_rtt", "is_analysis" : false } ], "tag_fields" : [ { "field_name" : "hostIP", "is_analysis" : true } ], "template_type" : "built_in", "template_name" : "ELB", "template_id" : "", "quick_analysis" : false }
-
Modifying a VPC system template
https://{endpoint}/v3/{project_id}/lts/struct/template { "log_group_id" : "17f23e52-a23d-46e0-8bc5-xxxxxxxxxxxx", "log_stream_id" : "b4d56d47-b4c4-453e-9047-xxxxxxxxxxxx", "demo_fields" : [ { "field_name" : "version" }, { "field_name" : "project_id" }, { "field_name" : "interface_id" }, { "field_name" : "srcaddr" }, { "field_name" : "dstaddr" }, { "field_name" : "srcport" }, { "field_name" : "dstport" }, { "field_name" : "protocol" }, { "field_name" : "packets" }, { "field_name" : "bytes" }, { "field_name" : "start" }, { "field_name" : "end" }, { "field_name" : "action" }, { "field_name" : "log_status" } ], "tag_fields" : [ { "field_name" : "hostIP", "is_analysis" : true } ], "template_type" : "built_in", "template_name" : "VPC", "template_id" : "", "quick_analysis" : false }
Example Responses
Status code: 201
The request is successful.
None
Status code: 400
Invalid request. Modify the request based on the description in error_msg before a retry.
{ "error_code" : "LTS.2014", "error_msg" : "Failed to create struct config." }
Status code: 500
The server has received the request but encountered an internal error.
{ "error_code" : "LTS.2016", "error_msg" : "Failed to update struct config" }
Status Codes
Status Code |
Description |
---|---|
201 |
The request is successful. |
400 |
Invalid request. Modify the request based on the description in error_msg before a retry. |
500 |
The server has received the request but encountered an internal error. |
Error Codes
See Error Codes.
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.See the reply and handling status in My Cloud VOC.
For any further questions, feel free to contact us through the chatbot.